We supply standard-compliant materials and professional application for concrete repair, waterproofing, industrial floor coatings, FRP/Carbon wrap strengthening, as well as roof and façade rehabilitation. Suitable for factories, hospitals, malls, and residential projects.
Choosing the right system and workflow is key to a durable restoration. PPCWORLD advises by standards and real site conditions.
Concrete
Structural repair mortars (R3/R4)
Polymer-modified mortars with high compressive strength and adhesion for column bases, beams, slabs, and water tanks. Thixotropic for vertical/sag-resistant areas; Flowable for form-and-pour.
Compressive strength: 40–70 MPa (28d)
Low shrinkage, micro-crack control
Compatible with existing steel & concrete
Waterproofing
PU/Epoxy Injection – crack & leak treatment
PU foams to stop water instantly; Epoxy seals cracks for structural durability. For basements, tanks, lift pits.
Low viscosity, deep penetration
Applied with 300–500 bar pumps
Use steel packers; drilled injection ports
Flooring
Epoxy/PU industrial floor systems
Self-leveling, high-build, or antistatic systems for factories, pharma, and F&B. Includes crack, flatness, and moisture treatment prior to coating.
Thickness: 0.3–3.0 mm
Chemical & abrasion resistance
Cleanable, hygienic finishes
Strengthening
FRP / Carbon wrap
Increase flexural/shear capacity of beams and columns using carbon fabric with structural epoxy resins. Low-intrusion, minimal downtime.
Ideal where loads increase or use changes
Dry, fast installation with clear QA/QC
Roof
Roof waterproofing & recovery
Liquid-applied membranes, torch-on membranes, or TPO/EPDM for concrete and metal roofs. Butyl tapes & adhesives for joints and pipe penetrations.
Design life 10–20 years
Heat-reflective options reduce HVAC load
Façade
Façade panels & coatings
Beauty + durability: lightweight cladding panels, pure acrylic/silicate coatings, treatment for hairline cracks and peeling.
Note: For substrate moisture >4%, use a moisture barrier before coating.
Quick Specs
Typical figures (reference only – request specific TDS per brand/product).
R4 repair mortar
Property
Reference value
Compressive strength, 28d
≥ 60 MPa
Elastic modulus
≥ 20 GPa
Adhesion to concrete
≥ 1.5 MPa
Shrinkage
< 0.5 mm/m
Floor coating systems
Item
Reference
Thickness
0.5–3.0 mm
Required substrate moisture
< 4% (or use moisture barrier)
Re-opening to traffic
24–72 h depending on system
FAQ
Do we need to shut down production lines during floor restoration?
We can phase the work and rotate lines. Some scopes allow quick re-opening in 24–48 hours.
Can carbon wrap replace additional concrete jacketing?
Not completely. Carbon wrap is suitable for localized strengthening with minimal intrusion when loads increase moderately or architecture must be preserved.
Is PU injection permanent?
PU stops water quickly; for long-term performance combine with epoxy crack sealing and source waterproofing.